~~Title:PUHZ-SHW230YKA~~ ====== Unidad Exterior PUHZ-SHW230YKA ====== ===== Foto ===== {{ :atw:producto:foto_puhz-shw230yka.jpg?200 |}} ===== Especificaciones básicas ===== ^Modelo ^^ Estándar ^^''PUHZ-SHW230YKA'' ^ ^::: ^^ Versión ''-BS'' ^^ ^ |Tipo |||| Split R410A | |Tecnología |||| Zubadan | |Capacidad | [[#calefaccion|Calefacción]] (A7W35) || [kW] | 23,0 | |::: | [[#refrigeracion|Refrigeración]] (A35W18) || [kW] | 20,0 | |Datos de \\ alimentación \\ eléctrica | Alimentación ||| <3F>, 400V, 50Hz | |::: |Corriente máx. || [A] | 26 | |::: |Tamaño PIA || [A] | 32 | |::: |Cableado || [mm2] | 4 × 10 + | |Datos de \\ instalación | [[#dimensiones|Dimensiones]] | Al×An×Fo | [mm] | 1338×1050×330 | |::: |::: |Peso | [kg] | 149 | |::: |[[#curvas_de_criterio_sonoro|Nivel sonoro]] |SPL (Calor) | [dB] | 59 | |::: |::: |SPL (Frío) | [dB] | 58 | |::: |::: |PWL (Calor) | [dB] | 75 | |::: |Caudal del ventilador || [m3/min] | 140 | |Datos \\ frigoríficos | Diámetros \\ Tuberías | Líquido | [mm (″)] | 12,70 (1/2) | |::: |::: | Gas | [mm (″)] | 25,40 (1) | |::: |Distancias \\ máximas | Altura | [m] | 30 | |::: |::: | Total | [m] | 80 | |::: |Gas \\ refrigerante | Tipo (PCA) || R410A (2088) | |::: |::: | Precarga | [kg] | 7,7 | |::: |::: |::: | [m] | 30 | |Datos del \\ circuito \\ hidráulico \\ primario | Tª impulsión | Calor (Máx.) | [ºC] | 60 | |::: |::: | Frío (Mín.) | [ºC] | 5 | |::: |Caudal de trabajo || [/min] | 28,7 ~ 65,9 | |::: |Volumen \\ mínimo | Cl. med/cál | [] | 33 | |::: |::: | Clima frío| [] | 99 | |Rango de \\ Tª exterior \\ operativa | Calefacción || [ºC] | -25 ~ +21 | |::: | Refrigeración || [ºC] | -15 ~ +46 | |::: | Producción de ACS || [ºC] | -25 ~ +35 | ^Unidades \\ interiores \\ compatibles | Hydrobox((Necesita el adaptador de tubería ''[[PAC-SG73RJ-E]]'')) | F/C ||''[[ERSE-YM9ED]]''| |::: |::: | ::: ||''[[ERSE-MED]]'' | |::: |::: | S/C ||''[[EHSE-YM9ED]]'' | ^Accesorios \\ compatibles | Placa de control FTC6 |||''[[PAC-IF071B-E]]'' | |::: | Placa de control FTC2BR |||''[[PAC-IF033B-E]]'' | |::: | Tratamiento Blygold(r) |||''[[ATW-BLY-2VN]]'' | |::: | Deflector de salida de aire |||''[[PAC-SG96SG-E]]'' × 2 | |::: | Guía de protección de viento |||''[[PAC-SH95AG-E]]'' × 2 | |::: | Tapones/guía drenaje |||''[[PAC-SG61DS-E]]'' | |::: | Bandeja centralizada drenaje |||''[[PAC-SH97DP-E]]'' | |::: | Herramienta de monitorización |||''[[PAC-SK52ST-E]]'' | |::: | Adaptador de tubería líquido 3/8"->1/2" |||''[[PAC-SG73RJ-E]]'' | ===== Dimensiones ===== {{ :atw:producto:dim_puhz-shw230yka.jpg?600 |}} ===== Esquema eléctrico ===== {{ :atw:producto:wiring_puhz-shw230yka.jpg?400 |}} ===== Esquema frigorífico ===== {{ :atw:producto:refrig_puhz-shw230yka.jpg?600 |}} ===== Datos de rendimiento ===== * Datos de referencia mostrados a temperaturas de agua de impulsión de 35ºC, 40ºC, 45ºC, 50ºC, 55ºC y 60ºC. * Se muestran los regímenes de trabajo **Máximo**, **Nominal**, **Medio** (80% del Nominal) y **Mínimo** del compresor. * Los datos resaltados así integran la función de desescarche. * El rendimiento real puede variar según las condiciones de funcionamiento. * El símbolo indica que el circuito de inyección está activado. * Datos medidos según **EN 14511:2013**. ==== Refrigeración ==== | ^^ Temperatura de impulsión [ºC] ^^^^ |::: ^^ 7 ^^ 18 ^^ ^Rég. ^ Tª ^ Cap. ^ EER ^ Cap. ^ EER ^ ^::: ^ [ºC] ^ [kW] ^::: ^ [kW] ^::: ^ ^Máx.^ 35 | 20,0 | 2,22 | 24,0 | 2,65 | ^:::^ 30 | 21,1 | 2,46 | 25,1 | 2,89 | ^:::^ 25 | 22,6 | 2,88 | 26,6 | 3,34 | ^:::^ 20 | 22,4 | 2,88 | 26,0 | 3,20 | ^Nom.^ 35 | 20,0 | 2,22 | 20,0 | 3,55 | ^:::^ 30 | 20,0 | 2,60 | 20,0 | 4,09 | ^:::^ 25 | 20,0 | 3,19 | 20,0 | 4,85 | ^:::^ 20 | 20,0 | 3,35 | 20,1 | 3,90 | ^Med.^ 35 | 16,0 | 2,47 | 16,0 | 4,15 | ^:::^ 30 | 16,0 | 2,88 | 17,4 | 4,43 | ^:::^ 25 | 16,0 | 3,48 | 17,6 | 4,82 | ^:::^ 20 | 16,0 | 3,83 | 20,1 | 3,90 | ^Mín.^ 35 | 8,9 | 2,98 | 13,7 | 4,37 | ^:::^ 30 | 11,9 | 3,24 | 17,4 | 4,43 | ^:::^ 25 | 12,3 | 3,69 | 17,6 | 4,82 | ^:::^ 20 | 14,4 | 3,24 | 20,1 | 3,90 | ==== Calefacción ==== | ^^ Temperatura de impulsión [ºC] ^^^^^^^^^^^^^^ |:::^^ 25 ^^ 35 ^^ 40 ^^ 45 ^^ 50 ^^ 55 ^^ 60 ^^ ^Rég. ^ Tª ^ Cap. ^ COP ^ Cap. ^ COP ^ Cap. ^ COP ^ Cap. ^ COP ^ Cap. ^ COP ^ Cap. ^ COP ^ Cap. ^ COP ^ ^:::^ [ºC] ^ [kW] ^:::^ [kW] ^:::^ [kW] ^:::^ [kW] ^:::^ [kW] ^:::^ [kW] ^:::^ [kW] ^:::^ ^Máx.^ -25 | - | - | 16,4 | 1,48 | 16,0 | 1,30 | - | - | - | - | - | - | ^:::^ -20 | 20,3 | 2,06 | 19,8 | 1,84 | 19,3 | 1,62 | - | - | - | - | - | - | ^:::^ -15 | 22,9 | 2,20 | 22,7 | 2,00 | 22,5 | 1,80 | 21,6 | 1,61 | 20,8 | 1,41 | - | - | ^:::^ -10 | 25,6 | 2,34 | 25,6 | 2,16 | 25,7 | 1,98 | 25,7 | 1,84 | 25,6 | 1,69 | - | - | ^:::^ -7 | 27,1 | 2,43 | 27,4 | 2,26 | 27,7 | 2,09 | 28,1 | 1,98 | 28,4 | 1,86 | - | - | ^:::^ 2 | 23,2 | 2,29 | 23,0 | 2,16 | 22,9 | 2,02 | 22,8 | 2,02 | 22,8 | 2,02 | 22,7 | 1,98 | ^:::^ 7 | 28,0 | 3,28 | 27,9 | 3,07 | 27,9 | 2,85 | 27,7 | 2,65 | 27,5 | 2,42 | 26,3 | 2,05 | ^:::^ 12 | 29,5 | 3,48 | 29,3 | 3,21 | 29,1 | 2,94 | 28,8 | 2,75 | 28,5 | 2,54 | 27,4 | 2,24 | ^:::^ 15 | 30,5 | 3,60 | 30,2 | 3,30 | 29,8 | 3,00 | 29,5 | 2,82 | 29,1 | 2,61 | 28,2 | 2,35 | ^:::^ 20 | 32,1 | 3,80 | 31,6 | 3,45 | 31,1 | 3,09 | 30,6 | 2,92 | 30,1 | 2,73 | 29,3 | 2,54 | ^Nom.^ -25 | - | - | 16,4 | 1,48 | 16,0 | 1,30 | - | - | - | - | - | - | ^:::^ -20 | 20,3 | 2,06 | 19,8 | 1,84 | 19,3 | 1,62 | - | - | - | - | - | - | ^:::^ -15 | 22,9 | 2,20 | 22,7 | 2,00 | 22,5 | 1,80 | 21,6 | 1,61 | 20,8 | 1,41 | - | - | ^:::^ -10 | 23,0 | 2,60 | 23,0 | 2,36 | 23,0 | 2,12 | 23,0 | 1,99 | 23,0 | 1,85 | - | - | ^:::^ -7 | 23,0 | 2,85 | 23,0 | 2,58 | 23,0 | 2,32 | 23,0 | 2,22 | 23,0 | 2,11 | - | - | ^:::^ 2 | 23,0 | 2,37 | 23,0 | 2,16 | 22,9 | 2,02 | 22,8 | 2,02 | 22,8 | 2,02 | 22,7 | 1,98 | ^:::^ 7 | 23,0 | 3,65 | 23,0 | 3,34 | 23,0 | 3,02 | 23,0 | 2,76 | 23,0 | 2,47 | 23,0 | 2,09 | ^:::^ 12 | 24,3 | 4,10 | 24,3 | 3,68 | 24,3 | 3,26 | 24,3 | 2,98 | 24,3 | 2,67 | 24,3 | 2,34 | ^:::^ 15 | 25,7 | 4,29 | 25,7 | 3,84 | 25,7 | 3,39 | 25,7 | 3,10 | 25,7 | 2,79 | 25,7 | 2,49 | ^:::^ 20 | 28,1 | 4,61 | 28,1 | 4,10 | 28,1 | 3,59 | 28,1 | 3,31 | 28,1 | 2,99 | 28,1 | 2,75 | ^Med.^ -25 | - | - | 13,1 | 1,68 | 12,8 | 1,55 | - | - | - | - | - | - | ^:::^ -20 | 16,2 | 2,00 | 15,8 | 1,87 | 15,4 | 1,73 | - | - | - | - | - | - | ^:::^ -15 | 18,3 | 2,36 | 18,2 | 2,16 | 18,0 | 1,97 | 17,3 | 1,82 | 16,6 | 1,66 | - | - | ^:::^ -10 | 18,4 | 2,72 | 18,4 | 2,46 | 18,4 | 2,21 | 18,4 | 2,06 | 18,4 | 1,90 | - | - | ^:::^ -7 | 18,4 | 2,93 | 18,4 | 2,64 | 18,4 | 2,35 | 18,4 | 2,21 | 18,4 | 2,05 | - | - | ^:::^ 2 | 18,4 | 2,90 | 18,4 | 2,60 | 18,3 | 2,30 | 18,3 | 2,26 | 18,2 | 2,21 | 18,1 | 2,08 | ^:::^ 7 | 18,4 | 4,01 | 18,4 | 3,58 | 18,4 | 3,14 | 18,4 | 2,83 | 18,4 | 2,49 | 18,4 | 2,24 | ^:::^ 12 | 19,4 | 4,58 | 19,4 | 4,05 | 19,4 | 3,52 | 19,4 | 3,15 | 19,4 | 2,76 | 19,4 | 2,55 | ^:::^ 15 | 20,6 | 4,91 | 20,6 | 4,34 | 20,6 | 3,76 | 20,6 | 3,37 | 20,6 | 2,96 | 20,6 | 2,74 | ^:::^ 20 | 22,5 | 5,55 | 22,5 | 4,89 | 22,5 | 4,23 | 22,5 | 3,80 | 22,5 | 3,34 | 22,5 | 3,05 | ^Mín.^ -25 | - | - | 13,1 | 1,68 | 12,8 | 1,55 | - | - | - | - | - | - | ^:::^ -20 | 16,2 | 2,00 | 15,8 | 1,87 | 15,4 | 1,73 | - | - | - | - | - | - | ^:::^ -15 | 18,3 | 2,36 | 18,2 | 2,16 | 18,0 | 1,97 | 17,3 | 1,82 | 16,6 | 1,66 | - | - | ^:::^ -10 | 18,4 | 2,72 | 18,4 | 2,46 | 18,4 | 2,21 | 18,4 | 2,06 | 18,4 | 1,90 | - | - | ^:::^ -7 | 12,6 | 2,72 | 12,1 | 2,41 | 11,6 | 2,10 | 10,7 | 1,83 | 9,7 | 1,53 | - | - | ^:::^ 2 | 11,8 | 3,52 | 11,3 | 3,11 | 10,8 | 2,70 | 10,0 | 2,35 | 9,1 | 1,97 | - | - | ^:::^ 7 | 11,4 | 4,31 | 10,5 | 3,73 | 9,6 | 3,15 | 8,4 | 2,64 | 7,2 | 2,10 | - | - | ^:::^ 12 | 11,4 | 5,08 | 10,4 | 4,39 | 9,4 | 3,70 | 8,3 | 3,39 | 7,2 | 3,05 | - | - | ^:::^ 15 | 13,5 | 5,58 | 12,4 | 4,87 | 11,4 | 4,17 | 10,4 | 3,85 | 9,5 | 3,49 | - | - | ^:::^ 20 | 20,0 | 5,94 | 19,1 | 5,29 | 18,3 | 4,63 | 17,5 | 4,21 | 16,7 | 3,75 | - | - | ===== Rango disponible ===== ^ Calefacción ^ Refrigeración ^ |{{ :atw:producto:qrh-puhz-shw230yka.jpg?400 |}}|{{ :atw:producto:qrc-puhz-shw230yka.jpg?400 |}}| Asegúrese de evitar el rango no disponible durante los desescarches. De lo contrario, la unidad exterior podría no haberse desecho de toda la escarcha y/o el PHEX se podría congelar. ===== Temperaturas máximas de impulsión ===== {{ :atw:producto:maxt_puhz-shw140-230_a.jpg?400 |}} ===== Curvas de criterio sonoro ===== {{ :atw:producto:pos_micro_nc.jpg?nolink&200|}} * Datos sonoros tomados con el sistema en régimen estable. * Cuando la V4V o la LEV entran en funcionamiento se puede escuchar un sonido relativamente mayor. {{ :atw:producto:nc_puhz-shw230yka.jpg?400 |}} ===== Nivel sonoro estimado en función de la distancia a la OU ===== {{ :atw:producto:pos_micro_nc.jpg?nolink&200|}} * Datos sonoros tomados con el sistema en régimen estable. * Cuando la V4V o la LEV entran en funcionamiento se puede escuchar un sonido relativamente mayor. * No se considera la reflexión de sonido desde el suelo o paredes aledañas. {{ :atw:producto:spl_puhz-shw230yka.jpg?400 |}} ===== Eficiencia energética estacional ===== ==== Calefacción de espacios ==== |:::^Tipo IU ^^ F/C ^^ S/C ^^ |:::^ Hydrobox ^ Con RdA^ ''[[ERSE-YM9ED]]'' |[[erp1>shw230he_002_001.pdf|Ficha ErP]]^ ''[[EHSE-YM9ED]]'' |[[erp1>shw230he_002_001.pdf|Ficha ErP]]| |:::^::: ^ Sin RdA^ ''[[ERSE-MED]]'' |:::^ -- | -- | | Media Tª \\ (55ºC) | Clase || A++ || A++ || |::: | s / SCOP | Clima medio | 128% / 3,28 || 127% / 3,25 || |::: | ::: | Clima cálido | 150% / 3,83 || 149% / 3,80 || |::: | ::: | Clima frío | 124% / 3,18 || 123% / 3,15 || | Baja Tª \\ (35ºC) | Clase || A++ || A++ || |::: | s / SCOP | Clima medio | 165% / 4,20 || 164% / 4,18 || |::: | ::: | Clima cálido | 202% / 5,13 || 199% / 5,05 || |::: | ::: | Clima frío | 164% / 4,18 || 162% / 4,13 || ===== Recursos externos ===== === Lodotec === * [[lodotec>Databook/202112_ATW_DATABOOK_R410A_Vol4.2.pdf]] * [[lodotec>Tecnico/OCH594C.pdf]] * [[lodotec>Despiece/OCB594D.pdf]] * [[lodotec>Certificados/CE2020A15_PUHZ-SHW230YKA2.pdf]] === EHPA Keymark === * [[keymark>1768|ECODAN ZUBADAN 23]]: Con ''ERSE'', ''EHSE'' === Archivos BIM === * [[mep>27452|Ecodan PUHZ-SHW-YKA]]